Water meter connection points for multi-dwelling buildings MCP System
www.plasson.co.uk
MCP System What is the PLASSON MCP System
The PLASSON MCP system allows the division of the mains water supply and the installation of a water meter for individual properties in multi-dwelling buildings as required by guidelines and requirements of the UK Water Utility companies and the Water Supply (Water Fittings) Regulations:
Isolate the incoming water main / boosted water supply Split incoming water supply by way of manifold Isolate water supply to individual dwelling Provide connection point for class D water meter (normally supplied by Water Utility company) Provide backflow prevention, with serviceable double check valve (ED suitable for fluid category 3) Provide a drain point for the property, with the individual property main isolated Allow connection to all proprietary plumbing pipework systems PLASSON MCP Unit Developed as a monobloc design unit to allow quick and easy installation: The new MCP removes the need for several components to be joined together. The new design provides a compact solution and can be supplied with connections to suit the wide variety and size range of pipe systems in use today. PLASSON MCP Manifolds The new PLASSON manifold offer brings a totally flexible approach to connecting multiple properties in one location, such as communal riser cupboards and plant rooms.
The 63mm PP-RCT header can be supplied as a one piece unit with between 2 and 16 outlets to suit each installation.
Plain ended manifolds can be supplied with pre-fitted PLASSON mechanical fittings, either straight couplings, elbows or tee’s and can incorporate a full bore mains stop valve to isolate the manifold.
Tel 01444 244446
sales@plasson.co.uk
www.plasson.co.uk
2
The PLASSON MCP System Combined The combination of the new MCP unit and the manifold system brings a complete new dimension to the M&E contractor and plumber providing a simple and cost effective system to this often overlooked but vitally important part of any building infrastructure. The MCP unit is manufactured from high grade engineering polypropylene, and the manifold system from PP-RCT, all components approved to UK Water Reg4 either by Kiwa KUKreg4 or WRAS approvals. Combined with the extensive range of PLASSON fittings and Mains Stop Valves, the new PLASSON MCP system provides an unrivalled solution for all stake holders involved in the domestic and commercial mechanical services sector.
Tel 01444 244446
sales@plasson.co.uk
www.plasson.co.uk
MCP System MCP (Meter Connection Point)
The new PLASSON MCP (meter connection point) provides mains isolation, meter connection, drain point and back flow prevention in a compact one piece unit.
Designed specifically for multi-occupancy buildings, such as apartments and high-rise, the PLASSON MCP can be fitted at each apartment, or more commonly it can simply be connected to the PLASSON multi-port manifold system located in a riser or plant room.
Drain cap
Double check valve
Valve handle
Drain spigot
Meter seat plug
O ring
O ring
Key Features Quarter turn high flow mains stop valve
1 1/2” Class D concentric meter connection with full flow Approved double check valve built in under meter seat Drain point for draining pipework downstream of water meter (the property) whilst isolating the main supply while in drain position Space saving monobloc design for quick and easy installation NBR & EPDM sealing throughout for complete water tight integrity Kiwa UK Regulation 4 (KUKreg4) approved
3/4” BSPP Brass 3/4” FI parallel loose nut for connection to 3/4” MI fittings to create a union type joint.
Push-Fit Fittings For connection to Copper/PB/PEX.
Mechanical Fittings For connection to PE or adapting to other pipe types.
Tel 01444 244446
sales@plasson.co.uk
www.plasson.co.uk
4
MCP System
Technical specification
Double check valve
Drain Cap
Valve Handle
Meter seat Plug
H
L
W
Product Codes
Code
Description
L
H
W
PM0351071897007 PM0351071897022 PM0351071897028 PM0351071897025 PM0351071897032
MCP 3/4” BSPP x 3/4” BSPP
264 274 274 280 285
125 125 125 125 125
80 80 80 80 80
MCP 3/4” BSPP x 22mm Cu/PB/PEX MCP 3/4” BSPP x 28mm Cu/PB/PEX
MCP 3/4” BSPP x 25mm PE MCP 3/4” BSPP x 32mm PE
Other inlet and outlet connections are available. Please contact your PLASSON ASM for details.
Specification
A UK Water Regulation 4 approved one piece meter carrier consisting of, in the following sequence: quarter turn mains isolation valve, connection point for Class D water meter, serviceable double check valve (ED suitable for fluid category 3) and drain point. Unit with 1” ISO 228 threads to allow connection of PLASSON fittings for various pipe connections.
Technical Details: Maximum Operating Pressure
Water PN16
Water Meter Connection
DN40 internal thread
Maximum Operating Temperature
23°C
Material
High grade polypropylene copolymer body, EPDM ‘O’ rings and seal
Note: The MCP unit has ‘O’ rings on the male threads that seal only the special PLASSON mechanical and pushfit fittings supplied with the MCP, these require no additional sealing materials which could compromise the ‘O’ ring seal. To install the PLASSON fitting onto the thread, engage the threads and screw the fitting on firmly by hand. The 1” x 3/4” meter union, seals with flat washers supplied, wrench tighten.
The meter seat plug is for initial testing but is also suitable for long term use if required. It is ‘O’ ring sealed, if removed to fit a meter, please also remove the seal and use the seals supplied with the meter. It is a full-flow plug.
Tel 01444 244446
sales@plasson.co.uk
www.plasson.co.uk
5
MCP System
Multiport Manifolds
The PLASSON Multiport Manifold system is designed to connect incoming water mains and enable separation into individual supply pipes for connection of multiple dwellings. Combined with our MCP meter connection point, the PLASSON MCP system provides a complete solution for water meter connection in any multi occupancy building. An extensive range of one piece construction manifolds are available with between 3 and 16 outlets. There are two options for connecting the incoming supply, and outlets at either 130mm centres, allowing meter faces to line up, or 90mm centres alternately staggered, both meeting the water utility companies installation requirements for water meters.
Key Features One piece construction from PP-RCT 2 to 16 outlet ports from 63mm header End Supply and Centre Supply options
Plain end for connection with PLASSON fitting or 2” MI BSP connection 130mm straight or 90mm staggered centres to allow meter installation position as per Water Utility company requirements Specifically designed to work with the PLASSON MCP Meter connection point Available with or without drain port
Tel 01444 244446
sales@plasson.co.uk
www.plasson.co.uk
6
Manifold Dimensions End Supply
30
Plain End Inlet For connection using PLASSON 63mm mechanical fittings with PP-RCT adaptor.
63Ø
200
130
130
90
Example with 130mm centres
150
30
2”Threaded MI Inlet Example with 90mm centres
63Ø
115
90
90
90
90
End Supply Manifold - Plain End Inlet
Max overall length in mm
Number of Outlets
3
4
5
6
7
8
9
10
11
12
13
14
15
16
90mm Centres
470 560 650 740 830 920 1010 1100 1190 1280 1370 1460 1550 1640 550 680 810 940 1070 1200 1330 1460 1590 1720 1850 1980 2110 2240
130mm Centres
End Supply Manifold - 2” MI Inlet
Max overall length in mm
Number of Outlets
3
4
5
6
7
8
9
10
11
12
13
14
15
16
90mm Centres
385 475 565 655 745 835 925 1015 1105 1195 1285 1375 1465 1555 465 595 725 855 985 1115 1245 1375 1505 1635 1765 1895 2025 2155
130mm Centres
Centre Supply
210
150
30
63Ø
90
130
90
90
Centre Supply Example Showing 130mm centre dimensions on left 90mm centre dimensions on right
H = Threaded - 205mm Plain - 200mm
H
2” MI Threaded or 63mm plain options available
Centre Supply Manifolds Number of Outlets
Max overall length in mm
2
4
5
6
7
8
9
10
11
12
13
14
15
16
90mm Centres
- 570 660 750 840 930 1020 1110 1200 1290 1380 1470 1560 1650 390 650 780 910 1040 1170 1300 1430 1560 1690 1820 1950 2080 2210
130mm Centres
Tel 01444 244446
sales@plasson.co.uk
www.plasson.co.uk
MCP System
End Supply Manifolds
130mm centres Plain end
90mm centres Plain end
130mm Centres - Plain End
PORTS
90mm Centres - Plain End
PORTS
PM3525E 3A02 PM3525E 4A02 PM3525E 5A02 PM3525E 6A02 PM3525E 7A02 PM3525E 8A02 PM3525E 9A02 PM3525E 10A02 PM3525E 11A02 PM3525E 12A02 PM3525E 13A02 PM3525E 14A02 PM3525E 15A02 PM3525E 16A02
PM3525E 3B02 PM3525E 4B02 PM3525E 5B02 PM3525E 6B02 PM3525E 7B02 PM3525E 8B02 PM3525E 9B02 PM3525E 10B02 PM3525E 11B02 PM3525E 12B02 PM3525E 13B02 PM3525E 14B02 PM3525E 15B02 PM3525E 16B02
3 4 5 6 7 8 9
3 4 5 6 7 8 9
10 11 12 13 14 15 16
10 11 12 13 14 15 16
130mm centres 2” MI end
90mm centres 2” MI end
130mm Centres - 2” MI End
PORTS
90mm Centres - 2” MI End
PORTS
PM3525E 3B03 PM3525E 4B03 PM3525E 5B03 PM3525E 6B03 PM3525E 7B03 PM3525E 8B03 PM3525E 9B03 PM3525E 10B03 PM3525E 11B03 PM3525E 12B03 PM3525E 13B03 PM3525E 14B03 PM3525E 15B03 PM3525E 16B03
3 4 5 6 7 8 9
3 4 5 6 7 8 9
PM3525E 3A03 PM3525E 4A03 PM3525E 5A03 PM3525E 6A03 PM3525E 7A03 PM3525E 8A03 PM3525E 9A03 PM3525E 10A03 PM3525E 11A03 PM3525E 12A03 PM3525E 13A03 PM3525E 14A03 PM3525E 15A03 PM3525E 16A03
Drain off cock (DOC) for manifolds
10 11 12 13 14 15 16
10 11 12 13 14 15 16
Code Description PM3525DOC Drain point for PP-RCT manifold To add a DOC to any of the above manifolds, order code PM3525DOC for each manifold ordered.
Tel 01444 244446
sales@plasson.co.uk
www.plasson.co.uk
8
MCP System
Centre Supply Manifolds
130mm centres Plain end
90mm centres Plain end
130mm Centres - Plain End
PORTS
90mm Centres - Plain End
PORTS
PM3525C 4B02 PM3525C 5B02 PM3525C 6B02 PM3525C 7B02 PM3525C 8B02 PM3525C 9B02 PM3525C 10B02 PM3525C 11B02 PM3525C 12B02 PM3525C 13B02 PM3525C 14B02 PM3525C 15B02 PM3525C 16B02
4 5 6 7 8 9
PM3525C 4A02 PM3525C 5A02 PM3525C 6A02 PM3525C 7A02 PM3525C 8A02 PM3525C 9A02 PM3525C 10A02 PM3525C 11A02 PM3525C 12A02 PM3525C 13A02 PM3525C 14A02 PM3525C 15A02 PM3525C 16A02
4 5 6 7 8 9
10 11 12 13 14 15 16
10 11 12 13 14 15 16
130mm centres 2” MI end
90mm centres 2” MI end
130mm Centres - 2” MI End
PORTS
90mm Centres - 2” MI End
PORTS
PM3525C 2B03 PM3525C 4B03 PM3525C 5B03 PM3525C 6B03 PM3525C 7B03 PM3525C 8B03 PM3525C 9B03 PM3525C 10B03 PM3525C 11B03 PM3525C 12B03 PM3525C 13B03 PM3525C 14B03 PM3525C 15B03 PM3525C 16B03
PM3525C 4A03 PM3525C 5A03 PM3525C 6A03 PM3525C 7A03 PM3525C 8A03 PM3525C 9A03 PM3525C 10A03 PM3525C 11A03 PM3525C 12A03 PM3525C 13A03 PM3525C 14A03 PM3525C 15A03 PM3525C 16A03
4 5 6 7 8 9
2 4 5 6 7 8 9
Drain off cock (DOC) for manifolds
10 11 12 13 14 15 16
10 11 12 13 14 15 16
Code Description PM3525DOC Drain point for PP-RCT manifold To add a DOC to any of the above manifolds, order code PM3525DOC for each manifold ordered.
Tel 01444 244446
sales@plasson.co.uk
www.plasson.co.uk
9
MCP System 3703 Mains Stop Valve - Above Ground Use
Full bore 1/4 turn ball valve with a drain port option, for mains isolation.
The 2” FI PLASSON 3703, UK Water Reg4 approved mains stop valve, is a non- metallic (light weight) ¼ turn full bore stop valve, which fully compliments the PLASSON MCP system. With its: Large, easy grip handle Drain/test port (no need to fit one) Connect direct to the MI manifold connection, or use PLASSON fittings to connect to a plain ended manifold
‘O’ ring sealed spindle for reliability.
Full bore (ultra-low headloss).
3703 Mains Stop Valve C/w drain / test ports Above ground only Fi x fi
Code
d
dn 50
PV037030F020
2”
With Drain For above ground use only Code With Drain Above Ground Only Size
DN X RC RP*
A1
A2
H
I
B
E
W
PLA37030F050
2”
50 x 2”
¼”
53
97
162
29
75
100
918
* Drain ports ISO 7/1 Rp, BSP thread.
Tel 01444 244446
sales@plasson.co.uk
www.plasson.co.uk
10
Scotland, & North East Aidan Brown aidan.brown@plasson.co.uk 07788 185671 North West & West Yorkshire TBC sales@plasson.co.uk 07788 185673 East Claire Burchell claire.burchell@plasson.co.uk 07841 066309 West Midlands & South Wales Harry Slade harry.slade@plasson.co.uk 07788 185669 South West Nick James nick.james@plasson.co.uk 07788 185675 South East Simon Denly simon.denly@plasson.co.uk 07788 185670 Area Sales Managers
Sales Director Victoria Fiddies victoria.fiddies@plasson.co.uk 07788 185672
Business Development Manager - MCP Adam Gatrell adam.gatrell@plasson.co.uk 07786 156954
Customer Support Manager Ruby Henry ruby.henry@plasson.co.uk 07788 185676 Technical Support Adam Cafer adam.cafer@plasson.co.uk 07788 185674