Large Diameter Saddles - Fitting Instructions | PLASSON UK

Installation Instructions

10

8

Tighten the belt by shifting the lever until the gap in the Tension Force Indicator (TFI) is closed. Check that the saddle surface is in full contact with the pipe.

Keep the belts tightened until the cooling time has elapsed.

Tension Force Indicator - indication for full tension

11

Loosen the belt by shifting the ratchet pulling device to its “loose” position.

9

IMPORTANT: Take off the belts, tightening plate and jig ring before making any connection to the saddle outlet!

12

Drill the pipe by using appropriate drill and cup-saw

Fuse the fitting according to ElectroFusion procedures.

SAFETY Follow carefully all the safety and operating instructions provided by the tool, the drill and the cup saw manufacturers.

IMPORTANT NOTICE The enclosed instructions should be regarded as general procedures to serve as a reminder for qualified Electrofusion welders.They are not intended to replace training and qualification. If you have not been certified as a qualified welder, you should do so prior to welding this fitting.

www.plasson.com