Installation Instructions
6
7
Fit the jig ring over the spigot outlet.
Shift the ratchet pulling device to its “loose” position, and attach it to the hooks that extend out of the tightening plate. Both pulling devices should be placed at the same side of the pipe.
Placed inside the spigot for sizes 125, 160 mm
Tension Force Indicator - indication at no tension
Placed outside the spigot for sizes 90, 110 mm
Shift the ratchet pulling device to its “locked” position.