Electrofusion - Installation Manual | PLASSON UK

Fitting data input

When using Plasson ElectroFusion fittings there are three possible methods for weld data transfer to the control box:

Plasson Smartfuse ® system relevant only to couplers in diameters 16mm up to 355mm.

What is the Plasson SmartFuse system?

• Self recognition system Automated recognition system that enables the compatible fusion controller to simply identify the welding time of the fitting. By connecting the red fusion cable from the Plasson control box to the Smart Pin, the identification process starts.

Smartfuse ® terminal pin

No further inputs or settings are necessary! Confirm that the weld time shown on the controller screen is identical to the weld time printed on the barcode label placed onto the product and just press the START button.

19